CARTA SPORT — User Manual

Updated May 19, 2025 5 min read

Your CARTA SPORT is designed for effortless sessions wherever life takes you. With one-button simplicity, Bluetooth connectivity, and support for all INTELLI-CORE® atomizers, it delivers power and convenience. The innovative CARTA CONNECT removable airpath ensures easy cleaning and endless possibilities.

Controls

  • 1 click — Cycle session presets
  • 2 clicks — Start / extend session (+10 sec)
  • 3 clicks — Cycle LED presets
  • 4 clicks — Check battery level
  • 5 clicks — Power ON / OFF
  • 1 click during session — Cancel session

Startup

  1. 1
    Charge before first use

    Connect via USB-C. Charging current must not exceed 5V / 2A. Always fully charge the device before using for the first time. Do not charge for more than 4 hours.

  2. 2
    Power on

    Press the V button 5 times. The device will display a startup LED animation.

  3. 3
    Select a session preset

    Press the V button once to display your current preset color. Press again to cycle to the next preset. Concentrate presets default to Blue (480°F, 60s).

  4. 4
    Load your concentrate

    Recommended load size is 0.1–0.3g. Avoid loading on the sides or near the top of the chamber. Use the FOCUS V SABER dab tool for precise loading.

  5. 5
    Start a session

    Double-tap the V button. The device vibrates and LEDs signal the session has started. When the target temperature is reached, the device vibrates again — begin drawing.

  6. 6
    Inhale

    Take slow, smooth pulls for the most consistent vapor production. To modulate airflow, slightly cover the carb cap opening.

  7. 7
    End session

    Press V once to cancel at any time. The session also ends automatically when the timer expires. Press V 5 times to power off.

Session presets

Concentrate presets (range: 365°F–635°F, 20s–120s):

  • Preset 1: Blue — 480°F, 60s
  • Preset 2: Yellow — 495°F, 55s
  • Preset 3: Green — 515°F, 50s
  • Preset 4: Purple — 535°F, 45s
  • Preset 5: Red — 565°F, 40s

Herb presets (range: 275°F–500°F, 120s–240s):

  • Preset 1: Blue — 340°F, 240s
  • Preset 2: Yellow — 350°F, 240s
  • Preset 3: Green — 370°F, 240s
  • Preset 4: Purple — 390°F, 240s
  • Preset 5: Red — 410°F, 240s

CONNECT airpath

CONNECT is a fully removable 100% silicone airpath designed for easy cleaning, precise reclaim management, and seamless glass top compatibility. Built-in channels make reclaim problems a thing of the past.

  1. 1
    Removal

    Remove the glass top and atomizer first. Carefully pull the front of CONNECT out first, then pull firmly from the center to remove completely.

  2. 2
    Installation

    Remove the atomizer and glass top. Align the airpath with the base and gently snap the rear section into position first, then push the front down ensuring proper fitment. Do not tear the silicone. Reinstall the atomizer then the glass top to complete setup.

Cleaning

Glass top

  1. 1
    Remove the glass top

    Power off the device and let it cool. Gently remove the glass top from the base.

  2. 2
    Rinse and fill with isopropyl

    Empty any leftover water, rinse with warm water, then fill the glass top with 70% isopropyl alcohol.

  3. 3
    Shake and rinse

    Cover the openings securely and shake vigorously to dissolve residue. Empty the alcohol, rinse thoroughly with water, and dry completely before reattaching.

Base and CONNECT airpath

  1. 1
    Remove glass top, atomizer, and CONNECT

    Carefully remove all components from the base.

  2. 2
    Clean the base

    Dampen a lint-free wipe with 70% isopropyl alcohol and gently clean visible residue from the base. Dry immediately — avoid prolonged liquid contact. Use a cotton swab for atomizer contacts and tight areas.

  3. 3
    Clean the CONNECT airpath

    Use isopropyl alcohol to clean the airpath, focusing on the reclaim channels. A cotton swab or small brush helps remove buildup. Rinse with warm water and allow to fully dry before reinstalling.

  4. 4
    Reassemble

    Snap the CONNECT airpath back into position, reinstall the atomizer, then reattach the glass top.

Atomizer

  1. 1
    Remove silicone parts

    Detach all silicone parts from the atomizer.

  2. 2
    Swab the chamber

    Gently swab the inside of the atomizer chamber with 70% isopropyl alcohol. Clean the atomizer threads with a cotton swab moistened with isopropyl.

  3. 3
    Soak

    Submerge only the atomizer in 70% isopropyl alcohol and soak for 5 minutes. Gentle agitation helps with thorough cleaning.

  4. 4
    Dry and reassemble

    Remove from soak and allow to air-dry completely. Inspect — if residue persists, repeat the soak. Once fully dry, reassemble all components. Run a brief low-temperature session before regular use.

Battery and charging

  • Battery: Li-ion Polymer, 2700mAh — 7.4V
  • Charging: 5V / 2A max — use only approved AC/DC adapter
  • Do not charge longer than 4 hours
  • Never leave the device charging unattended
  • For best battery longevity, avoid discharging below 60%
  • Do not expose to extreme temperatures, liquids, or direct sunlight

Battery level indicator — 4× V button clicks: Green ≥ 75% · Blue ≥ 50% · Yellow ≥ 25% · Red ≥ 10%

Tips & tricks

  • Load 0.1–0.3g — avoid overfilling; run multiple sessions for larger amounts
  • Slow, smooth pulls produce the most consistent vapor
  • Adjust timer settings to match your hit length — saves battery and prevents overheating
  • Swab the chamber after every session to minimize deep cleaning frequency
  • Warm 70% isopropyl alcohol dissolves residue more effectively
  • Check atomizer contacts and airpath regularly
  • Never use abrasives or caustic cleaners on the device

Warranty

  • CARTA SPORT Base: 1 Year
  • INTELLI-CORE Atomizer: 6 Months

Focus V warrants this device against defects in materials for one year from the retail purchase date (original end-user only). If a valid claim is received, Focus V will repair or exchange the product. Register your device and submit warranty claims at portal.focusv.com.

Was this article helpful?

Still need help?

Our support team is here for you. Submit a ticket and we'll get back to you within 1–2 business days.